CAD (0)
  • Cart is empty
  • Feeder Lengths - Cu

    Straight lengths can be supplied at any length from 23.6in - 9.84ft.

    The busplug slot outlet and cover are made from a durable, high strength, Class B, 130°C insulation material.

    The busplug slot cover prevents access to the contacts behind the cover and protects it from the entry of dirt, dust or moisture. Busplugs are IP55 as standard but higher levels up to IP67 can be provided upon request.

  • Distribution Length Cu IEC

    Straight lengths can be supplied at any length from 23.6in - 9.84ft.

    The busplug slot outlet and cover are made from a durable, high strength, Class B, 130°C insulation material.

    The busplug slot cover prevents access to the contacts behind the cover and protects it from the entry of dirt, dust or moisture. Busplugs are IP55 as standard but higher levels up to IP67 can be provided upon request.

  • Flatwise Elbow Cu IEC

    Flatwise elbows are used to make 90° changes in the direction of the busduct system. E+I Engineering can also manufacture specially angled elbows for both flatwise and edgewise products.

  • Edgewise Elbow Cu IEC

    Edgewise elbows are used to make 90° changes in the direction of the busduct system. E+I Engineering can also manufacture specially angled elbows for both flatwise and edgewise products.

  • Flatwise Offset Cu-IEC

    An offset is used to avoid any obstacles eg. pipes or to steel columns and to conform to the structure of the building.

  • Edgewise Offset Cu-IEC

    An offset is used to avoid any obstacles eg. pipes or to steel columns and to conform to the structure of the building.

  • Edge Right Flatwise Up Cu IEC

    Combination elbows are used to conform to the building’s structure and to change the direction of the busduct within a confined space.

  • Flatwise Up Edgewise Right Cu IEC

    Combination elbows are used to conform to the building’s structure and to change the direction of the busduct within a confined space.

  • Panel Flange Cu IEC

    Flange connections provide a direct connection to low voltage switchgear, transformer enclosures and other electrical equipment. Standard flanges can be offset to the left or right of the section as required.

  • Flatwise Elbow Flange Cu IEC

    A combination flange is used when the minimum leg lengths for either the standard elbow or the standard flange cannot be met.

  • Edgewise Elbow Flange Cu IEC

    A combination flange is used when the minimum leg lengths for either the standard elbow or the standard flange cannot be met.

  • Flatwise Tee Cu IEC

    Flatwise tee’s are used to split one busduct run into two runs going indifferent directions.

  • Expansion Unit Cu-IEC

    Expansion units are used to accommodate the expansion and contraction of a busduct system as well as allow for building movement. They allow for a 1.57” movement along the length of the busduct.

    Expansion units are recommended when a straight busduct run exceeds 196ft.

  • End Feed Unit IEC - Cu

    End feed units are used on the ends of busbar risers which are cable fed. They can be on top or the bottom of the busbar.

    The size of end feed required depends on a number of factors:

    • rating of busbar
    • size of cable
    • number of cables
    • use of a protective device or isolator

  • Center Feed Unit IEC - Cu

    Center feed units are used in the middle of busduct risers which are cable fed.

    The size of end feed required depends on a number of factors:

    • rating of busbar
    • size of cable
    • number of cables
    • use of a protective device or isolator

  • End Caps IEC

    End Caps

    (90)

    End caps are used to safely cap off the end of a busduct run. The end cap units are factory fitted but can be easily removed to allow for the extension of the system.

  • Joint Packs Cu-IEC

    Splice

    (90)

    E+I Engineering’s splice is a compression joint design utilising a specially designed Belleville washer to distribute the pressure evenly over the splice. The splice is supplied in specific sizes depending on the rating of busduct required.

  • Joint Elbow Pack IEC - Cu

    Flatwise elbow joint packs can be used to make 90° changes in the direction of the busbar system.

  • Joint Packs Tee Al_Cu-IEC

    Joint Pack tee’s are used to split one busbar run into two runs going in different directions.

  • HPB-CRB Transition Box - Cu
  • Fire Barrier